Misting Fan ConfiguratorMASTER2026-09-12T12:04:08+00:00 MISTEC AcademyMisting Fan ConfiguratorTell us about your project or enter the general equipment and materials you need. MISTEC will review the information and prepare the appropriate proposal. Step 10% Website Getting startedHow would you like to configure your system? Help me plan my systemDescribe the area, application, and available installation options. Photos, approximate dimensions, and a simple sketch are enough to begin.✓ I know what I needEnter the fan types, quantities, tubing, fittings, nozzles, and operating functions you already know.✓ Continue ApplicationWhat should the misting fans do? CoolingCool people, animals, work areas, patios, or processes with air movement and fine mist.✓HumidificationAdd moisture and circulate air in a room, greenhouse, warehouse, or production area.✓Dust controlMove air and apply mist near airborne dust or where dust is created.✓Odor controlDistribute water or an approved treatment product around an odor source.✓Mosquito controlDistribute an approved treatment product through fan-mounted misting rings.✓Other applicationChoose this if none of the listed applications describes your project.✓ Other application ?BackContinue Project environmentWhere will the system be installed? Installation environment ?OutdoorIndoorSemi-enclosedI do not know Type of project ?PrivateCommercialIndustrialAgriculturalPublic sectorOther Type of area ? Project city or region (optional) ? BackContinue Design conditionsWhat conditions should the system handle? Temperature unit ?Celsius (°C)Fahrenheit (°F) Highest daytime temperature (optional) ? Lowest relative humidity (optional) ?% Required relative humidity ?% Dust or material type (optional) ? Treatment requirements (optional) ? BackContinue Area dimensionsWhat are the approximate dimensions of the area? Area length (optional) ? Area width (optional) ? Available mounting height (optional) ? BackContinue VentilationWhat do you know about the building ventilation? Information available ?I do not knowAir changes per hour (ACH)Supply or exhaust airflow Air changes per hour (ACH) ?ACH Airflow unit ?m³/hCFMOutside-air or exhaust airflow ? Doors, openings, and ventilation details (optional) ? BackContinue Fan installationHow can the fans be installed? Wall mountedFans can be fixed to walls, posts, or structural columns.✓ Ceiling or roof mountedFans can hang from a suitable overhead structure.✓ Mobile or floor standingFans should be movable or installed on floor stands.✓ Large industrial box fansThe building can support high-output box fans at a higher mounting position.✓ I do not knowMISTEC should recommend a practical mounting method.✓ Mounting restrictions (optional) ?BackContinue Fan preferenceDo you have a preferred fan type? Please recommendMISTEC will select the fan type and estimated quantity from the area and installation information.✓ 20-inch wall fan - oscillatingCompact wall-mounted fan for targeted cooling. The 90-degree oscillation distributes air and mist across a wider area.✓20-inch hanger fan - fixedFixed ceiling- or roof-mounted fan for directing airflow and mist toward one defined area.✓24-inch wall fan - oscillatingHigh-output wall fan for medium-size cooling areas. Oscillation spreads the airflow and mist across the installation area.✓30-inch wall fan - oscillatingLarge wall-mounted fan for higher airflow and wider open areas.✓36-inch mobile blower fanMobile high-output fan for flexible, directional cooling where permanent wall mounting is not practical.✓140 cm box fanHighest-capacity standard box fan for large industrial or agricultural cooling areas and higher mounting positions.✓Another fan or existing fansChoose this if fans are already installed or another fan type must be used.✓ Existing or other fan details ?BackContinue Misting fansWhich fans and quantities do you need?Published coverage is marked as such. All other coverage ranges are preliminary estimates based on catalog airflow and the published MISTEC installation examples. MISTEC will verify the final quantity and placement.20-inch wall fan - oscillatingCompact wall-mounted fan for targeted cooling. The 90-degree oscillation distributes air and mist across a wider area.Coverage: Approximately 30-40 m²Published installation guide50 cm fan9,500 m³/h / 5,590 CFM90-degree oscillation220-240 V, 50/60 Hz88 W43 dB(A)Quantity (pcs)20-inch hanger fan - fixedFixed ceiling- or roof-mounted fan for directing airflow and mist toward one defined area.Coverage: Approximately 24-30 m²Published installation guide50 cm fan6,500 m³/h / 3,830 CFMFixed, non-oscillating220-240 V, 50/60 Hz75 W42.2 dB(A)Quantity (pcs)24-inch wall fan - oscillatingHigh-output wall fan for medium-size cooling areas. Oscillation spreads the airflow and mist across the installation area.Coverage: Approximately 50-60 m²Published installation guide60 cm fan12,500 m³/h / 7,360 CFM90-degree oscillation220-240 V, 50/60 Hz167 W42.2 dB(A)Quantity (pcs)30-inch wall fan - oscillatingLarge wall-mounted fan for higher airflow and wider open areas.Coverage: Estimated 60-75 m²Preliminary estimate based on airflow and published fan benchmarks80 cm fan15,000 m³/h / 8,830 CFM90-degree oscillation220-240 V, 50/60 Hz139 W42.2 dB(A)Quantity (pcs)36-inch mobile blower fanMobile high-output fan for flexible, directional cooling where permanent wall mounting is not practical.Coverage: Estimated 60-80 m²Preliminary estimate based on airflow and published fan benchmarks90 cm fan15,800 m³/h / 9,300 CFMMobile trolley, 360-degree positioning220-240 V, 50/60 Hz312 W56 dB(A)Quantity (pcs)80 cm box fanFixed industrial box fan for high-volume airflow in production, agricultural, or large covered areas.Coverage: Estimated 55-70 m²Preliminary airflow-based estimate from the published 140 cm benchmark80 cm housing11,000 m³/h / 6,500 CFMFixed mounting400 V, 50 Hz370 WQuantity (pcs)100 cm box fanFixed industrial box fan for high-volume airflow across larger work or agricultural areas.Coverage: Estimated 75-95 m²Preliminary airflow-based estimate from the published 140 cm benchmark100 cm housing15,000 m³/h / 8,800 CFMFixed mounting400 V, 50 Hz370 WQuantity (pcs)120 cm box fanHigh-capacity fixed box fan for large industrial or agricultural spaces.Coverage: Estimated 135-170 m²Preliminary airflow-based estimate from the published 140 cm benchmark120 cm housing27,000 m³/h / 15,900 CFMFixed mounting400 V, 50 Hz560 WQuantity (pcs)140 cm box fanHighest-capacity standard box fan for large industrial or agricultural cooling areas and higher mounting positions.Coverage: Approximately 200-250 m²Published installation guide140 cm housing40,000 m³/h / 23,500 CFMFixed mounting400 V, 50 Hz745 WQuantity (pcs)Other fan requirements (optional) ?BackContinue Misting ringsWhich misting rings do you need?Enter the number of complete rings. The standard nozzle quantity is calculated automatically from the selected rings.32 cm misting ring - 4 nozzlesAISI 316 stainless steel ring with four 10/24-inch threaded nozzle positions and a 1/4-inch female hose connection.For approximately 45-50 cm fansQuantity (complete rings)40 cm misting ring - 5 nozzlesAISI 316 stainless steel ring with five 10/24-inch threaded nozzle positions and a 1/4-inch female hose connection.For approximately 60 cm fansQuantity (complete rings)47 cm misting ring - 8 nozzlesAISI 316 stainless steel ring with eight 10/24-inch threaded nozzle positions and a 1/4-inch female hose connection.For approximately 60-100 cm fansQuantity (complete rings)80 cm misting ring - 8 nozzlesAISI 316 stainless steel ring with eight 10/24-inch threaded nozzle positions and a 1/4-inch female hose connection.For approximately 100-140 cm fansQuantity (complete rings)Custom misting ringsComplete this section only if you need a special ring diameter or a different number of nozzles.Number of custom rings (optional) ?Fan diameter for the custom ring (optional) ?cmRequired ring diameter (optional) ?cmNozzles per custom ring (optional) ?Additional custom ring details (optional) ?BackContinue UtilitiesWhat power supply and pump location are available? Measurement system ?Metric (meters)Imperial (feet) Electrical supply for the fans ?I do not know220-240 V / single-phase / 50 Hz400 V / three-phase / 50 Hz120 V / single-phase / 60 Hz220-240 V / single-phase / 60 Hz460 V / three-phase / 60 HzOtherOther fan electrical supply ? Electrical supply at the pump location ?I do not know220-240 V / single-phase / 50 Hz400 V / three-phase / 50 Hz120 V / single-phase / 60 Hz220-240 V / single-phase / 60 Hz460 V / three-phase / 60 HzOtherOther pump electrical supply ? Distance from pump to the first fan (optional) ? Possible pump location (optional) ? BackContinue TubingWhat tubing system do you prefer? Please recommendMISTEC will choose the tubing sizes and routing after reviewing the fan layout and pump position.✓Nylon high-pressure tubingFlexible tubing for the main supply, branches, and connections to oscillating fans.✓Stainless steel main tubingRigid stainless steel pipe for fixed main routes, with flexible connections where fan movement requires them.✓ Main high-pressure tubing (optional) ?Branch and fan-connection tubing (optional) ?BackContinue Fittings and accessoriesWhich fittings do you need?Push-lock elbowTurns nylon high-pressure tubing 90 degrees without bending it sharply.Quantity (pcs)Push-lock teeDivides one high-pressure tubing route into two branches.Quantity (pcs)Push-lock cross fittingConnects four tubing directions at one distribution point.Quantity (pcs)Push-lock line endCloses the end of a nylon high-pressure tubing route.Quantity (pcs)ClampsClamps secure the tubing or pipe to the building. Leave the quantity empty if MISTEC should calculate it from the final layout.Quantity (pcs)Stainless steel elbowTurns a rigid stainless steel tubing route 90 degrees.Quantity (pcs)Stainless steel teeDivides one stainless steel route into two branches.Quantity (pcs)Stainless steel cross fittingConnects four stainless steel tubing directions at one distribution point.Quantity (pcs)Stainless steel line endCloses the end of a stainless steel high-pressure route.Quantity (pcs)ClampsClamps secure the tubing or pipe to the building. Leave the quantity empty if MISTEC should calculate it from the final layout.Quantity (pcs)Misting ringsFan-mounted rings that distribute the nozzles around the fan outlet.Quantity (pcs)Flexible fan connectionsFlexible high-pressure connections between the fixed supply route and each moving or oscillating fan.Quantity (pcs)Manual isolation valvesValves used to isolate an individual fan or branch during service.Quantity (pcs)BackContinue NozzlesWhat do you know about the nozzles? Please recommendMISTEC will select the nozzle quantity, material, and orifice for the application and fan.✓Stainless steel nozzlesCorrosion-resistant nozzles for professional high-pressure misting systems.✓Noxid nozzlesNickel-plated brass nozzles available in several orifice sizes.✓ Nozzle orifice ?Please recommend0.15 mm / .006"0.20 mm / .008"0.30 mm / .012"0.40 mm / .015"0.50 mm / .020"Spare nozzles (optional) ?BackContinue Pump and controlHow should the system operate? Please recommendMISTEC will determine whether a fixed-flow or variable-flow pump is appropriate.✓Fixed flow rateAll selected fans and nozzles normally operate together.✓Variable flow rate (VAR)Different fan groups or zones may operate independently.✓ Preferred control locationPlease recommendMISTEC will select a practical control method for the approved system.✓Control at the pumpThe required timer, temperature, or humidity function should be integrated into the pump when available.✓Separate external controlControls should be installed away from the pump or coordinated with fans or building equipment.✓No automatic control requiredThe system only needs basic manual or external on/off operation.✓Required control functionsCyclic mist and pause operationAlternate adjustable spraying and pause periods.✓Daily or weekly scheduleOperate automatically on selected days and times.✓Temperature controlStart and stop according to the selected temperature.✓Humidity controlStart and stop according to the selected relative humidity.✓Remote or building-system controlAllow operation from another controller or building-management system.✓BackContinue Additional functionsWhat else should the system include?Water filtrationInclude suitable filtration, or review filtration already available at the site.✓Water disinfectionReview whether UV or another water-treatment method is needed.✓Dosing a treatment productA substance must be added to the water for odor, mosquito, or another treatment application.✓Separate operating zonesDifferent groups of fans must operate independently.✓Coordinate fans and mistingThe fan operation and the high-pressure misting system should be controlled together.✓Additional requirements (optional) ?BackContinue Project detailsWhat else should MISTEC know?Project description ?Photos, plans, or sketches (optional) ?BackContinue Contact informationWhere should we send our response?Company (optional)First nameLast nameEmailCountryPhone (optional) I agree that MISTEC may use this information to review my request and contact me about this project.BackSubmit Request
20-inch wall fan - oscillatingCompact wall-mounted fan for targeted cooling. The 90-degree oscillation distributes air and mist across a wider area.Coverage: Approximately 30-40 m²Published installation guide50 cm fan9,500 m³/h / 5,590 CFM90-degree oscillation220-240 V, 50/60 Hz88 W43 dB(A)Quantity (pcs)
20-inch hanger fan - fixedFixed ceiling- or roof-mounted fan for directing airflow and mist toward one defined area.Coverage: Approximately 24-30 m²Published installation guide50 cm fan6,500 m³/h / 3,830 CFMFixed, non-oscillating220-240 V, 50/60 Hz75 W42.2 dB(A)Quantity (pcs)
24-inch wall fan - oscillatingHigh-output wall fan for medium-size cooling areas. Oscillation spreads the airflow and mist across the installation area.Coverage: Approximately 50-60 m²Published installation guide60 cm fan12,500 m³/h / 7,360 CFM90-degree oscillation220-240 V, 50/60 Hz167 W42.2 dB(A)Quantity (pcs)
30-inch wall fan - oscillatingLarge wall-mounted fan for higher airflow and wider open areas.Coverage: Estimated 60-75 m²Preliminary estimate based on airflow and published fan benchmarks80 cm fan15,000 m³/h / 8,830 CFM90-degree oscillation220-240 V, 50/60 Hz139 W42.2 dB(A)Quantity (pcs)
36-inch mobile blower fanMobile high-output fan for flexible, directional cooling where permanent wall mounting is not practical.Coverage: Estimated 60-80 m²Preliminary estimate based on airflow and published fan benchmarks90 cm fan15,800 m³/h / 9,300 CFMMobile trolley, 360-degree positioning220-240 V, 50/60 Hz312 W56 dB(A)Quantity (pcs)
80 cm box fanFixed industrial box fan for high-volume airflow in production, agricultural, or large covered areas.Coverage: Estimated 55-70 m²Preliminary airflow-based estimate from the published 140 cm benchmark80 cm housing11,000 m³/h / 6,500 CFMFixed mounting400 V, 50 Hz370 WQuantity (pcs)
100 cm box fanFixed industrial box fan for high-volume airflow across larger work or agricultural areas.Coverage: Estimated 75-95 m²Preliminary airflow-based estimate from the published 140 cm benchmark100 cm housing15,000 m³/h / 8,800 CFMFixed mounting400 V, 50 Hz370 WQuantity (pcs)
120 cm box fanHigh-capacity fixed box fan for large industrial or agricultural spaces.Coverage: Estimated 135-170 m²Preliminary airflow-based estimate from the published 140 cm benchmark120 cm housing27,000 m³/h / 15,900 CFMFixed mounting400 V, 50 Hz560 WQuantity (pcs)
140 cm box fanHighest-capacity standard box fan for large industrial or agricultural cooling areas and higher mounting positions.Coverage: Approximately 200-250 m²Published installation guide140 cm housing40,000 m³/h / 23,500 CFMFixed mounting400 V, 50 Hz745 WQuantity (pcs)
32 cm misting ring - 4 nozzlesAISI 316 stainless steel ring with four 10/24-inch threaded nozzle positions and a 1/4-inch female hose connection.For approximately 45-50 cm fansQuantity (complete rings)
40 cm misting ring - 5 nozzlesAISI 316 stainless steel ring with five 10/24-inch threaded nozzle positions and a 1/4-inch female hose connection.For approximately 60 cm fansQuantity (complete rings)
47 cm misting ring - 8 nozzlesAISI 316 stainless steel ring with eight 10/24-inch threaded nozzle positions and a 1/4-inch female hose connection.For approximately 60-100 cm fansQuantity (complete rings)
80 cm misting ring - 8 nozzlesAISI 316 stainless steel ring with eight 10/24-inch threaded nozzle positions and a 1/4-inch female hose connection.For approximately 100-140 cm fansQuantity (complete rings)
ClampsClamps secure the tubing or pipe to the building. Leave the quantity empty if MISTEC should calculate it from the final layout.Quantity (pcs)
Stainless steel cross fittingConnects four stainless steel tubing directions at one distribution point.Quantity (pcs)
ClampsClamps secure the tubing or pipe to the building. Leave the quantity empty if MISTEC should calculate it from the final layout.Quantity (pcs)
Flexible fan connectionsFlexible high-pressure connections between the fixed supply route and each moving or oscillating fan.Quantity (pcs)
Manual isolation valvesValves used to isolate an individual fan or branch during service.Quantity (pcs)